Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-107-
Set
value
Function
Description
43
HDO
HDO from the programmable card
44
RO1
RO1 from the programmable card
45
RO2
RO2 from the programmable card
46
RO3
RO3 from the programmable card
47
RO4
RO4 from the programmable card
48
EC PT100 detected OH pre-alarm
Pre-alarm of overheating (OH) detected by the
expansion card (EC) with PT100.
49
EC PT1000 detected OH
pre-alarm
Pre-alarm of OH detected by the EC with PT1000.
50
AI/AO detected OH pre-alarm
Pre-alarm of OH detected by AI/AO.
51
Stopped or running at zero speed
The VFD is in stopped state or running at zero
speed.
52
Disconnection detected in tension
control
Disconnection is detected when the disconnection
detection is enabled in tension control.
53
Roll diameter setting reached
The set roll diameter is reached during running in
tension control.
54
Max. roll diameter reached
The max. roll diameter is reached during running
in tension control.
55
Min. roll diameter reached
The min. roll diameter is reached during running in
tension control.
56
Fire control mode enabled
The fire mode is turned on.
57
–63
Reserved
Related parameter list:
Function
code
Name
Description
Default
HDO output type
0: Open collector high-speed pulse output
1: Open collector output
0