Goodrive350A series high-performance multifunction VFD
Function parameter list
-220-
Function
code
Name
Description
Default
value
Modify
method
1: Pulse detection method
2: Pulse detection method
P13.02
Pull-in current 1
Pull-in current is the pole positioning current.
Pull-in current 1 is valid within the lower limit
of pull-in current switchover frequency
threshold. If you need to increase the starting
torque, increase the value of the function code
properly.
Setting range: 0.0%
–100.0% (of the motor
rated current)
20.0%
○
P13.03
Pull-in current 2
Pull-in current is the pole positioning current.
Pull-in current 2 is valid within the upper limit
of pull-in current switchover frequency
threshold. Generally, you do not need to
modify the function code.
Setting range: 0.0%
–100.0% (of the motor
rated current)
10.0%
○
P13.04
Pull-in current
switchover
frequency
0.0%
–200.0% (of the motor rated current)
20.0%
○
P13.05
Reserved
P13.06
Pulse current
setting
Used to set the pulse current threshold when
the initial magnetic pole position is detected
by means of pulse. The value is a percentage
in relative to the rated current of the motor.
Setting range: 0.0
–300.0% (of the motor rated
voltage)
100.0%
◎
P13.07
Reserved
P13.08 Control parameter 1 0x0000
–0xFFFF
0x0000
○
P13.09
Frequency
threshold of
phase-lock loop
switch-in
This parameter is used to set the frequency
threshold for enabling the
counter-electromotive force phase-locked
loop in SVC 0. When the running frequency is
lower than the value of this parameter, the
phase-locked loop is disabled; and when the
50.00
○