Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-99-
Setting
Function
Description
71
Switch to mater
In stopped state, if the terminal is valid, the master is
used.
72
Switch to slave
In stopped state, if the terminal is valid, the slave is used.
73
Reset roll diameter
Used to reset the roll diameter when the tension control
function is enabled.
74
Switch winding/unwinding
Used to switch winding/unwinding modes when the
tension control function is enabled.
75
Tension control pre-drive
If the terminal is valid when the tension control function is
enabled, tension control pre-drive is performed.
76
Disable roll diameter
calculation
If the terminal is valid when the tension control function is
enabled, roll diameter calculation is disabled.
77
Clear alarm display
Used to clear the alarm display when the tension control
function is enabled.
78
Manual braking of tension
control
If the terminal is valid when the tension control function is
enabled, manual braking is activated.
79
Trigger forced feeding
interrupt
If the terminal is valid when the tension control function is
enabled, a feeding interrupt signal is triggered forcibly.
80
Initial roll diameter 1
Used to select different initial roll diameters by combining
with the initial roll diameter 2 when the tension control
function is enabled.
81
Initial roll diameter 2
Used to select different initial roll diameters by combining
with the initial roll diameter 1 when the tension control
function is enabled.
82
Trigger fire mode control
In fire mode, if the terminal is valid, the fire mode control
signal is triggered.
83
Switch tension PID
parameters
Used to switch two PID parameter groups when the
tension control function is enabled. The first group is
used by default. If the terminal is valid, the second group
is used.