Goodrive350A series high-performance multifunction VFD
Function parameter list
-280-
Function
code
Name
Description
Default
Modify
setting
Ones place: At stop
0: Remain current roll diameter
1: Restore to initial roll diameter
Tens place: Power off at running
0: Remain current roll diameter
1: Restore to initial roll diameter
Hundreds place: Reach the roll diameter set
value
0: Remain current roll diameter
1: Restore to initial roll diameter
Thousands place: Terminal reset limitation
0: Reset allowed at running
1: Reset only allowed at stop
P90.28
Tension PID output
reference
0
–1
0: Max. value
1: Given value
0
○
P90.29
Tension PID
parameter source
0
–5
0: First group of P90
1: Roll diameter (max. roll diameter)
2: Main reference frequency (max. Frequency)
3: Running linear speed (max. linear speed)
4: Deviation (Reference 100%)
5: Terminal
0
○
P90.30
Group 1
proportional gain
0.000
–30.000
0.030
○
P90.31
Group 1 integral
time
0.00
–30.00s
5.00s
○
P90.32
Group 1 differential
time
0.00
–10.00s
0.00s
○
P90.33
Group 2
proportional gain
0.000
–30.000
0.030
○
P90.34
Group 2 integral
time
0.00
–30.00s
5.00s
○
P90.35
Group 2 differential
time
0.00
–10.00s
0.00s
○
P90.36
PID parameter
adjustment
0.0%
–P90.37
10.0%
○