Goodrive350A series high-performance multifunction VFD
Function parameter list
-185-
Function
code
Name
Description
Default
Modify
if you enter an incorrect password. Please
remember your password and save it in a
secure place.
After you exit the function code editing
interface, the password protection function is
enabled within 1 minute. If password
protection is enabled, "
0.0.0.0.0
" is
displayed when you press the PRG/ESC key
again to enter the function code editing
interface. You need to enter the correct user
password to enter the interface.
Note:
Restoring the default values may
delete the user password. Exercise caution
when using this function.
P07.01
Reserved
P07.02
Key function
selection
Range: 0x00
–0x27
Ones place: Function of QUICK/JOG
0: No function
1: Jog
2: Reserved
3: Switch between forward and reverse
rotating
4: Clear the UP/DOWN setting
5: Coast to stop
6: Switch command channels in sequence
7: Reserved
Tens place: Reserved
0x01
◎
P07.03
Sequence of
switching
running-command
channels by
pressing QUICK
When P07.02=6, set the sequence of
switching running-command channels by
pressing this key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal
←→Communication
0
○
P07.04
Stop function
validity of
The function code specifies the stop function
validity of STOP/RST. For fault reset,
0
○