Goodrive350A series high-performance multifunction VFD
Function parameter list
-236-
Function
code
Name
Description
Default
value
Modify
Bit0: S1
Bit1: S2
Bit2: S3
Bit3: S4
Bit4: HDIA
Bit5: HDIB
Range: 0x00
–0x3F
P17.13
Digital output
terminal state
Displays current digital output terminal state of
the VFD.
0x00
–0x0F
Bit0: Y1
Bit1: HDO
Bit2: RO1
Bit3: RO2
0x00
●
P17.14
Digital adjustment
value
Displays the regulating variable of
UP/DOWN.
Range: 0.00Hz
–P00.03
0.00Hz
●
P17.15
Torque reference
value
Relative to percentage of the rated torque of
current motor, display torque reference.
Range: -300.0%
–300.0% (motor rated
current)
0.0%
●
P17.16
Linear speed
0
–65535
0
●
P17.17
Reserved
P17.18
Counting value
0
–65535
0
●
P17.19
AI1 input voltage
Displays input signal of AI1
Range: 0.00
–10.00V
0.00V
●
P17.20
AI2 input voltage
Displays input signal of AI2
Range: -10.00V
–10.00V
0.00V
●
P17.21
HDIA input
frequency
Displays input frequency of HDIA
Range: 0.000
–50.000kHz
0.000
kHz
●
P17.22
HDIB input
frequency
Displays input frequency of HDIB
Range: 0.000
–50.000kHz
0.000 kHz
●
P17.23 PID reference value
Displays PID reference value
Range: -100.0
–100.0%
0.0%
●