Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-96-
Setting
Function
Description
current frequency.
27
Wobbling frequency reset
(revert to center frequency)
The set frequency of VFD reverts to center frequency.
28
Counter reset
Zero out the counter state.
29
Switching between speed
control and torque control
The VFD switches from torque control mode to speed
control mode, or vice versa.
30
Acceleration/deceleration
disabled
Ensure the VFD will not be impacted by external signals
(except for stop command), and maintains current output
frequency.
31
Counter trigger
Enable pulse counting of the counter.
33
Clear frequency
increase/decrease setting
temporarily
When the terminal is closed, the frequency value set by
UP/DOWN can be cleared to restore to the frequency
given by frequency command channel; when the terminal
is disconnected, it will revert to the frequency value after
frequency increase/decrease setting.
34
DC brake
The VFD starts DC braking immediately after the
command becomes valid.
35
Switching between motor 1
and motor 2
When this terminal is valid, you can realize switchover
control of two motors.
36
Command switches to keypad
When this terminal is valid, the running command
channel will switch to keypad compulsorily. If this function
becomes invalid, the running command channel will
revert to the original state.
37
Command switches to
terminal
When this terminal is valid, the running command
channel will switch to terminal compulsorily. If this
function becomes invalid, the running command channel
will revert to the original state.
38
Command switches to
communication
When this terminal is valid, the running command
channel will switch to communication compulsorily. If this
function becomes invalid, the running command channel
will revert to the original state.