Setting
Function
Description
55
Enable cyclic digital
positioning
Cyclic positioning can be enabled when digital
positioning is valid.
56
Emergency stop
When this command is valid, the motor decelerate to
emergency stop as per the time set by P01.26.
57
Motor overtemperature fault
input
Motor stops at motor over-temperature fault input.
59
Switch from FVC to SVPWM
control
When this terminal is valid in stop state, switch to
SVPWM control.
60
Switch to FVC control
When this terminal is valid in stop state, switch to FVC
(closed-loop vector) control.
61
PID polarity switchover
Switching the output polarity of PID, this terminal should
be used in conjunction with P09.03
62
Reserved
63
Enable servo
When the thousands place of P21.00 is set to enable the
servo, the servo enabling terminal is valid, which controls
the VFD to enter zero servo control. At this situation, no
startup command is needed.
64
FWD max. limit
Max frequency limit on forward rotation
65
REV max limit
Max frequency limit on reverse rotation
66
Zero out the counter
Zero out the position counting value
67
Pulse increase
When the terminal function is valid, the pulse input is
increased according to the P21.27 pulse speed.
68
Enable pulse superimposition
When the pulse superimposition is enabled, pulse
increase and pulse decrease are effective.
69
Pulse decrease
When the terminal function is valid, the pulse input is
decreased according to the P21.27 pulse speed.
70
Electronic gear selection
If the terminal is valid, the proportional numerator is
switched to the P21.30 numerator of the 2
nd
command
ratio.