Goodrive350A series high-performance multifunction VFD
Function parameter list
-163-
Function
code
Name
Description
Default
Modify
Output voltage
Output
frequency
Cut-off
boost
b
f
f
v
v
Setting range of P04.01: 0.0%: (automatic);
0.1%
–10.0%
Setting range of P04.02: 0.0%
–50.0%
P04.03
V/F frequency point
1 of motor 1
When P04.00=1 (multi-dot V/F curve), you
can set the V/F curve through
The V/F curve is generally set according to
the load characteristics of the motor.
Note:
V1 < V2 < V3, f1 < f2 < f3. Too high
voltage for low frequency will cause motor
overheat or damage and cause VFD
overcurrent stall or overcurrent protection.
Output voltage
Output
frequency(Hz)
V1
V2
V3
f1
f2
f3
100.0%
b
f
b
V
Setting range of P04.03: 0.00Hz
Setting range of P04.04: 0.0%
–110.0% (of the
rated voltage of motor 1)
Setting range of P04.05: P04.03
Setting range of P04.06: 0.0%
–110.0% (of the
rated voltage of motor 1)
Setting range of P04.07: P04.05
(rated frequency of AM 1) or P04.05
(rated frequency of SM 1)
Setting range of P04.08: 0.0%
–110.0% (of the
motor rated voltage of motor 1)
0.00Hz
○
P04.04
V/F voltage point 1
of motor 1
0.0%
○
P04.05
V/F frequency point
2 of motor 1
0.00Hz
○
P04.06
V/F voltage point 2
of motor 1
0.0%
○
P04.07
V/F frequency point
3 of motor 1
0.00Hz
○
P04.08
V/F voltage point 3
of motor 1
0.0%
○