Goodrive350A series high-performance multifunction VFD
Function parameter list
-255-
Function
code
Name
Description
Default
value
Modify
are valid for superposed pulses.
4: Input terminal function 28
The output terminal is valid during pulse
superposition, but it is invalid after pulse
superposition.
P21.29
Speed feedforward
filter time constant
(pulse train speed
mode)
It is the filter time constant detected by pulse
train when the speed reference source is set
to pulse train (when P00.06=12 or P00.07=12
Setting range: 0
–3200.0ms
10.0ms
○
P21.30
Numerator of the
2nd command ratio
1
–65535
1000
○
P21.31
Pulse reference
speed measuring
method
0
–2
0: Main control board
1: PG card
2: Hybrid
0
○
P21.32
Pulse reference
feedforward source
0x0
–0x1
0x0
◎
P21.33
Set value of
clearing encoder
count
0
–65535
0
◎
P22
—
Spindle positioning
Function
code
Name
Description
Default
value
Modify
P22.00
Spindle positioning
mode selection
0x0000
–0xFFFF
Bit0: Enable spindle positioning
0: Disable
1: Enable
Bit1: Select spindle positioning reference
point
0: Z pulse input
1: S2/S3/S4 terminal input
Bit2: Search for reference point
0: Search the reference point only once
1: Search the reference point every time
Bit3: Enable reference point calibration
0: Disable
1: Enable
0x0000
○