Goodrive350A series high-performance multifunction VFD
Function parameter list
-241-
Function
code
Name
Description
Default
value
Modify
and reverse orientation, which can be
eliminated by adjusting Z pulse direction of
P20.02 or exchanging phase AB of encoder.
0: Forward
1: Reverse
P18.12
Encoder Z pulse
angle
Reserved.
Range: 0.00
–359.99
0.00
●
P18.13
Encoder Z pulse
error times
Reserved.
Range: 0
–65535
0
●
P18.14
High-order bit of
encoder pulse
count value
Encoder pulse count value. The count value is
accumulated only if the VFD is powered on.
0
–65535
0
●
P18.15
Low-order bit of
encoder pulse
count value
Encoder pulse count value. The count value is
accumulated only if the VFD is powered on.
0
–65535
0
●
P18.16
Main control board
measured speed
value
-3276.8
–3276.7Hz
0.0Hz
●
P18.17
Pulse command
frequency
Pulse command (A2, B2 terminal) is
converted to the set frequency, and it is valid
under pulse position mode and pulse speed
mode.
Range: -3276.8
–3276.7Hz
0.00Hz
●
P18.18
Pulse command
feedforward
Pulse command (A2, B2 terminal) is
converted to the set frequency, and it is valid
under pulse position mode and pulse speed
mode.
Range: -3276.8
–3276.7Hz
0.00Hz
●
P18.19
Position regulator
output
-327.68
–327.67Hz
0.00Hz
●
P18.20
Count value of
resolver
Count value of resolver.
Range: 0
–65535
0
●
P18.21
Resolver angle
The pole position angle read according to the
resolver-type encoder.
Range: 0.00
–359.99
0.00
●
P18.22
Pole angle of
closed-loop SM
Current pole position.
Range: 0.00
–359.99
0.00
●
P18.23 Status control word 0
–65535
0
●