Goodrive350A series high-performance multifunction VFD
Function parameter list
-153-
Function
code
Name
Description
Default
Modify
1
5
12
60
116%
200%
Time (min)
Current overload
multiple
150%
180%
Setting range: 20.0%
–120.0%
P02.28
Power display
calibration
coefficient of motor
1
The function code can be used to adjust the
power display value of motor 1. However, it
does not affect the control performance of the
VFD.
Setting range: 0.00
–3.00
1.00
○
P02.29
Parameter display
selection of motor 1
0: Display by motor type. In this mode, only
parameters related to the present motor type
are displayed.
1: Display all. In this mode, all the motor
parameters are displayed.
0
○
P02.30
System inertia of
motor 1
0
–30.000kgm
2
0 kgm
2
○
P02.31
–
P02.32
Reserved
P03
—
Vector control of motor 1
Function
code
Name
Description
Default
Modify
P03.00
Speed-loop
proportional gain 1
The parameters P03.00
applicable only to vector control mode. Below
the switching frequency 1 (P03.02), the
speed-loop PI parameters are: P03.00 and
P03.01. Above the switching frequency 2
(P03.05), the speed-loop PI parameters are:
P03.03 and P03.04. PI parameters are
obtained according to the linear change of
20.0
○
P03.01
Speed-loop integral
time 1
0.200s
○
P03.02
Low-point
frequency for
switching
5.00Hz
○