Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-109-
Function
code
Name
Description
Default
34: Virtual terminal output of
EtherCAT/PROFINET/EtherNet IP
communication
35: Reserved
36: Speed/position control switchover
completed
37: Any frequency reached
38
–40: Reserved
41: Y1 from the programmable card
42: Y2 from the programmable card
43: HDO from the programmable card
44: RO1 from the programmable card
45: RO2 from the programmable card
46: RO3 from the programmable card
47: RO4 from the programmable card
48: EC PT100 detected OH pre-alarm
49: EC PT1000 detected OH pre-alarm
50: AI/AO detected OH pre-alarm
51: Stopped or running at zero speed
52: Disconnection detected in tension
control
53: Roll diameter setting reached
54: Max. roll diameter reached
55: Min. roll diameter reached
56: Fire control mode enabled
57
–63: Reserved
Output terminal polarity
selection
0x00
–0x0F
0x00
Y1 switch-on delay
0.000
–50.000s
0.000s
Y1 switch-off delay
0.000
–50.000s
0.000s
HDO switch-on delay
0.000
–50.000s (valid only when P06.00=1)
0.000s
HDO switch-off delay
0.000
–50.000s (valid only when P06.00=1)
0.000s
RO1 switch-on delay
0.000
–50.000s
0.000s
RO1 switch-off delay
0.000
–50.000s
0.000s
RO2 switch-on delay
0.000
–50.000s
0.000s
RO2 switch-off delay
0.000
–50.000s
0.000s
Output terminal status at
0