Goodrive350A series high-performance multifunction VFD
Function parameter list
-174-
Function
code
Name
Description
Default
Modify
COM
K
SB2
SB1
FWD
REV
SIn
The direction control is as follows during
running:
Sin
REV
Previous
direction
Present
direction
ON
OFF
→ ON
Run forward Run reversely
Run
reversely
Run forward
ON
ON→
OFF
Run
reversely
Run forward
Run forward Run reversely
ON→
OFF
ON
Decelerate to stop
OFF
Sin: Three-wire control; FWD: Forward
running; REV: Reverse running
3: Three-wire control 2. This mode defines
Sin as the enabling terminal, and the running
command is generated by FWD or REV, but
the direction is controlled by both FWD and
REV. During running, the Sin terminal needs
to be closed, and terminal FWD or REV
generates a rising edge signal to control the
running and direction of the VFD; the VFD
needs to be stopped by disconnecting
terminal Sin.