Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-85-
Function
code
Name
Description
Default
0: The setting made through UP/DOWN
is valid.
1: The setting made through UP/DOWN
is invalid.
Ones place: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency setting methods
2: Invalid for multi-step speed running
when multi-step speed running has the
priority
Hundreds place: Action selection for stop
0: Setting is valid.
1: Valid during running, cleared after stop
2: Valid during running, cleared after a
stop command is received
Frequency increment
change rate of the UP
terminal
0.01
–50.00 Hz/s
0.50 Hz/s
Frequency decrement
change rate of the DOWN
terminal
0.01
–50.00 Hz/s
0.50 Hz/s
Set frequency
0.00Hz
–P00.03 (Max. output frequency)
0.00Hz
Ramp reference frequency 0.00Hz
–P00.03 (Max. output frequency)
0.00Hz
Digital adjustment value
0.00Hz
0.00Hz
5.5.9 Analog input
The VFD provides two analog input terminals, which are AI1 supporting 0
–10V/0–20mA, (whether the
input is voltage or current can be set by P05.50), and AI2 supporting -10
–10V, and two high-speed
pulse input terminals. Each input can be filtered separately, and the corresponding reference curve
can be set by adjusting the reference corresponds to the max. value and min. value.