Goodrive350A series high-performance multifunction VFD
Function parameter list
-141-
Function
code
Name
Description
Default
Modify
communication
14: Programmable card
15: Reserved
P00.08
Reference object of
B frequency
command
0: Max. output frequency
1: A frequency command
0
○
P00.09
Combination mode
of setting source
0: A
1: B
2: (A+B)
3: (A- B)
4: Max(A, B)
5: Min. (A, B)
0
○
P00.10
Frequency set
through keypad
When A and B frequency commands select
the keypad for setting, the value of the
function code is the original setting one of the
frequency data of the VFD.
Setting range: 0.00 Hz
–P00.03 (Max. output
frequency)
50.00Hz
○
P00.11
ACC time 1
ACC time means the time needed if the VFD
speeds up from 0Hz to the max. output
frequency (P00.03).
DEC time means the time needed if the VFD
speeds down from the max. output frequency
(P00.03) to 0Hz.
The VFD has four groups of ACC/DEC time,
which can be selected by P05. The factory
default ACC/DEC time of the VFD is the first
group.
Setting range of P00.11 and P00.12:
0.0
–3600.0s
Model
depended
○
P00.12
DEC time 1
Model
depended
○
P00.13
Running direction
0: Run at the default direction.
1: Run at the opposite direction.
2: Disable reverse running
0
○