Goodrive350A series high-performance multifunction VFD
Function parameter list
-284-
Function
code
Name
Description
Default
Modify
selection
0: Inverse proportional curve
1: Multi-point curve
P91.28
Roll diameter value
1
0.0
–5000.0mm
200.0 mm
○
P91.29
Tension taper
coefficient for roll
diameter value 1
0.0
–50.0%
3.0%
○
P91.30
Roll diameter value
2
0.0
–5000.0mm
500.0 mm
○
P91.31
Tension taper
coefficient for roll
diameter value 2
0.0
–50.0%
7.0%
○
P91.32
Tension offset value
at zero speed
0.0
–300.0%
0.0%
○
P91.33
Present roll
diameter setting
0.0
–5000.0mm
0.0mm
◎
P92
—
Customized tension control functions
Function
code
Name
Description
Default
Modify
P92.00
Pre-drive speed
gain
0.0
–100.0%
100.0%
○
P92.01
Pre-drive torque
limit
0
–2
0: Set based on P03.20, P03.21
1: Set based on P93.02
2: Set based on the set tension
2
○
P92.02
Pre-drive torque
limit setting
0.0
–200.0%
100.0%
○
P92.03
Zero bit conversion
enabling
0
–1
0: Disable
1: Enable
0
◎
P92.04
Initial zero bit
0.0
–100.0%
10.0%
○
P92.05
Final zero bit
0.0
–100.0%
50.0%
○
P92.06
Conversion time
from initial zero bit
to final zero bit
0.00
–60.00s
5.00s
○
P92.07
Conversion time
from final zero bit to
0.00
–60.00s
5.00s
○