background image

CMMT-AS-C2/3/5-11A-P3-...-S1

Servo drive

Festo SE & Co. KG

Ruiter Straße 82

73734 Esslingen

Deutschland

+49 711 347-0

 

www.festo.com

Operating instructions | Installation, Safety sub-function
8165115

2021-12c

[8165117]

Translation of the original instructions

© 2021 all rights reserved to Festo SE & Co. KG

BiSS®, EnDat®, EtherCAT®, EtherNet/IP®, HEIDENHAIN®, Hiperface®,
MODBUS®, PI PROFIBUS PROFINET®, TORX® are registered trademarks of the
respective trademark owners in certain countries.

1

About this document

1.1

Target group

The document is targeted towards persons who mount and operate the product.
It is additionally targeted towards individuals who are entrusted with the plan-
ning and application of the product in a safety-related system (safety manual in
accordance with EN 61508).
1.2

Applicable documents

All available documents for the product 

è

  www.festo.com/sp.

The user documentation for the product also includes the following documents:

Identifier

Table of contents

Operating instructions for the
product

Installation, safety sub-function

Manuals for the product

Detailed description of assembly, installation
Detailed description of safety sub-function

Manual/online help plug-in

Plug-in:

Functions and operation of the software

Initial commissioning wizard

Firmware functions:

Configuration and parameterisation

Operating modes and operational functions

Diagnostics and optimisation

Bus protocol/control:

Device profile

Controller and parameterisation

Festo Automation Suite online
help

Function of the Festo Automation Suite

Management and integration of device-specific plug-ins

Operating instructions CDSB

General functions of the operator unit

Tab. 1: User documentation for the product

1.3

Product version

This documentation refers to the following version of the device:

Servo drive CMMT-AS-...-S1, revision R01 and higher, see product labelling

1.4

Product labelling

Observe the specifications on the product.

The product labelling is located on the right side of the device. The product label-
ling enables identification of the product and shows the following information,
for example:

Product labelling (example)

Meaning

CMMT-AS-C2-11A-P3-MP-S1

Order code

5340821  MM-YYYY : J302   Rev 00

Part number, serial number (MM = produc-
tion month, YYYY = production year, plant
number), revision (Rev)

Main input: 3 x 200 V AC - 10% 

 480 V AC + 10%

48 

 62 Hz 2 A

RMS

Technical data on power supply (alternating
current supply connection)

Motor out: 3 x 0 

 Input V AC   0 

 599 Hz

1.7 A

RMS

 0.8 kW

Technical data for the motor output (output
voltage, max. output frequency, nominal cur-
rent, nominal output power)

T

AMB

: max. 40 °C

Ambient temperature (T

AMB

)

IP10/20 PD2

Degree of protection, without mating plug/
with mating plug X9A attached; pollution
degree

Product labelling (example)

Meaning

SCCR: 10 kA
cUL restriction: only for use in WYE 480 V/277 V
supply sources

1)

SCCR (short circuit current rating)
Operation on power supply systems with SCCR

£

 10 kA 

è

 13.4 Technical data UL/CSA certifi-

cation

R-R-FTO-KC-2018-1054

KC mark certificate (test mark for Korea)

MAC: XX-XX-XX-XX-XX-XX

first MAC address of the device for Ethernet
communication

See manual for additional information

Reference to the existing user documentation,
which contains information on overload pro-
tection and the necessary external circuit
breaker.

Data matrix code 123456789AB

Product key as a data matrix code and an 11-
character alphanumeric code

Festo SE & Co. KG

Manufacturer

DE-73734 Esslingen

Manufacturer’s address

Made in Germany

Country of origin Germany

1) only for product versions with corresponding restrictions

Tab. 2: Product labelling (example)

Warning symbols on the front of the product

Warnin
g
symbol

Meaning with the CMMT-AS-...

Attention! Hot surface
Metallic housing parts of the device can reach high temperatures during operation.
In the event of a fault, internal components may become overloaded. Overloading of
components can result in high temperatures and the release of hot gases.
Attention! General danger point
The touch current in the protective earthing conductor can exceed an alternating cur-
rent of 3.5 mA or a direct current of 10 mA.
Always connect both protective earthing connections to the mains-side PE connection,
the PE pin of [X9A] and PE earthing screw on the housing.
The minimum cross section of the protective earthing conductor must comply with
the local safety regulations for protective earthing conductors for equipment with high
leakage current.

5 min

Attention! Dangerous voltage
The product is equipped with DC link capacitors, which store dangerous voltage for up
to 5 minutes after the power supply is switched off. Do not touch power connections for
5 minutes after the power supply is switched off.
After the power supply is switched off, wait at least 5 minutes until the DC link capaci-
tors have discharged.

Tab. 3: Meaning of the warning symbols

Warnings on the product
The following warnings are attached to the right side of the device:

Warnings on the product (en, fr)

Meaning

CAUTION
Risk of Electric Shock! Do not touch electrical connectors for
5 minutes after switching power off! Read manual before instal-
ling! High leakage current! First connect to earth!

Caution
Risk of electric shock! Do not
touch electrical connections
for 5 minutes after switching
power off! Read manual before
installing! High leakage current
after PE! First connect device to
protective earthing!

AVERTISSEMENT
Risque du choc électrique! Une tension dangereuse peut ètre pré-
sentée jusqu'à 5 minutes aprés avoir coupé l'alimentation ! Lire le
manuel avant installation ! Courant de défaut élevée ! Relier tout
d´abord à la terre !
DANGER
Risk of Electric Shock! Disconnect power and wait 5 minutes
before servicing.

Danger
Risk of electric shock! Discon-
nect power and wait 5 minutes
before servicing.

Risque du choc électrique! Débranchez l'alimentation et attendez
5 min. avant de procéder à l'entretien.
WARNING
Hot surface - Risk of burn!

Warning
Hot surface – danger of burns!

ATTENTION
Risque de temperature élevée en surface!

Tab. 4: Warnings on the product

1.5

Specified standards

Version

EN 61800-5-1:2007+A1:2017

EN 61800-2:2015

EN ISO 13849-1:2015

EN IEC 61800-3:2018

EN 60204-1:2018

EN 61800-5-2:2017

EN 60529:1991+A1:2000+A2/AC:2019

EN 62061:2005+AC:2010+A1:2013+A2:2015

EN 61508 Parts 1-7:2010

Tab. 5: Standards specified in the document

2

Safety

2.1

Safety instructions

General safety instructions

Assembly and installation should only be carried out by qualified personnel.

Only use the product if it is in perfect technical condition.

Only use the product in its original condition without unauthorised modifica-
tions.

Do not carry out repairs on the product. If defective, replace the product imme-
diately.

Содержание CMMT-AS-C2-11A-P3 S1 Series

Страница 1: ...nd the necessary external circuit breaker Data matrix code 123456789AB Product key as a data matrix code and an 11 character alphanumeric code Festo SE Co KG Manufacturer DE 73734 Esslingen Manufacturer s address Made in Germany Country of origin Germany 1 only for product versions with corresponding restrictions Tab 2 Product labelling example Warning symbols on the front of the product Warnin g ...

Страница 2: ...tor The safety sub function SBC is intended to safely hold the motor and axis in position at standstill The safety sub function SS1 is intended for performing a rapid stop with subse quent torque switch off 2 2 1 Application areas The device is intended for use in an industrial environment and with appropriate measures in commercial residential and mixed areas The device is intended for installati...

Страница 3: ...DC PELV 5 External braking resistor optional 6 Servo drive CMMT AS 7 Servo motor here EMME AS 8 PC with Ethernet connection for parameterisation 4 2 1 Overview of connection technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig 2 Connections of the CMMT AS C2 11A P3 example 1 PE connection housing 2 X9A Mains and DC link circuit connection 3 X9C Logic voltage 4 XF2 OUT RTE interface port 2 5 XF1 I...

Страница 4: ...r holding brakes or clamping units which engage in the de energised state Ensure the lines are protected when installed SBC request The safety sub function SBC is requested on 2 channels by simultaneously switching off the control voltage at both control inputs SBC A and SBC B The SBC A request switches off the power to the signals BR BR The SBC B request switches off the power to the signal BR EX...

Страница 5: ...for cross wiring For DC link coupling higher power devices must be placed closer to the mains supply If there is a voltage supply to the device when the control cabinet is open vertical access to the bottom and top of the device must be prevented For mounting on the rear wall of the control cabinet the servo drive cooling element has a slot on the top in the shape of a keyhole and an ordinary slot...

Страница 6: ... a DC current of 10 mA Always connect both protective earthing connections to the mains side PE connection the PE pin of X9A and PE earthing screw on the housing The minimum cross section of the protective earthing conductor must comply with the local safety regulations for protective earthing conductors for equipment with high leakage current 7 3 Mains fuse The CMMT AS does not have an integrated...

Страница 7: ...ernal mains filter Accessories Tab 16 Installation measures to achieve the specified category To install a line choke è 7 7 Connection examples If set up and commissioning are performed by a professional with the neces sary experience for setting up and commissioning drive systems including their EMC aspects category C2 devices can be used in the first environment residential area For operation of...

Страница 8: ...Control input Safe torque off channel B 10 SBC A Control input Safe brake control channel A X1A Pin Function Description 9 SBC B Control input Safe brake control channel B 8 reserved do not connect 7 6 5 4 ERR RST Error acknowledgement 3 CTRL EN Power stage enable 2 AIN0 Differential analogue input 1 AIN0 Tab 17 Inputs and outputs for the higher order PLC with the CMMT AS S1 Requirements for the c...

Страница 9: ...der emulation Incremental encoder input Input of a slave axis for receiving the encoder signals of a master axis Tab 24 Possible functions of the connection X10 Requirements for the connecting cable Characteristics Encoder cable for servo drives shielded Optical shield cover 85 Separately twisted signal pairs recommended design 4 x 2 x 0 25 mm2 Max cable length 3 m Tab 25 Requirements for the conn...

Страница 10: ...e potential 2 BR Holding brake positive potential 1 FE Functional earth con nected to protective earth Tab 34 Motor auxiliary connection Requirements for the connecting cable Design 2 wires for the line to the holding brake twisted in pairs separately shielded 2 wires for the line to the temperature sensor twisted in pairs separately shielded Min conductor cross section including wire end sleeve w...

Страница 11: ...th larger cable diameter 11 mm 15 mm 0 5 Nm 15 With a higher tightening torque make sure the con necting cable does not get crushed in the clamping area due to excessive pressure Tab 37 Tightening torque and clamping range CMMT AS C2 C3 C5 11A P3 1 2 3 4 5 Fig 11 Shield clamp of the motor cable 1 Retaining screws of the shield clamp 2 Motor cable 3 Cut out for mounting cable binders 2x 4 Shield cl...

Страница 12: ...resistors Information on selecting suitable braking resistors è Manual Assembly Installa tion 7 11 Cross wiring Cross wiring makes it possible to set up a device compound consisting of up to 10 servo drives CMMT AS The different cross wiring options are as follows Cross wiring of I O signals at the connection X1A Cross wiring of the mains and logic voltage supply without DC link coupling Cross wir...

Страница 13: ...d to connected components becoming overloaded or damaged Do not enable the closed loop controller until the configured components servo drive motor axis etc match those that are connected exactly During initial commissioning with the Festo Automation Suite with the CMMT AS plug in installed the following steps must be performed for example 1 Perform configuration and parameterisation with the CMMT...

Страница 14: ...he system against accidental reactivation 3 Wait at least 5 minutes until the intermediate circuit has discharged 4 Let the device cool down to room temperature 5 Before touching the power connections X6A X9A X9B check to ensure they are free of voltage 6 Disconnect all electrical cables To dismount the device Loosen retaining screws 2x and remove the device from the mounting sur face 13 Technical...

Страница 15: ...ge Storage temperature C 25 55 Relative humidity 5 95 non condensing Permissible altitude m 3000 above sea level Tab 58 Ambient conditions storage Ambient conditions operation Ambient temperature at nom inal power C 0 40 Ambient temperature with derating 3 C at 40 C 50 C C 0 50 Cooling via ambient air in the control cabinet from CMMT AS C5 11A P3 also via forced ventilation through an inte grated ...

Страница 16: ...ns of Underwriters Laboratories Inc UL for USA and Canada UL CSA certification information Product category code NMMS NMMS7 Power Conversion Equipment File number E331130_Vol 1_Sec 3 Considered standards UL61800 5 1 Adjustable Speed Electrical Power Drive Sys tems CSA C22 2 No 274 17 Adjustable Speed Drive UL mark UL control number 4PU8 Tab 65 UL CSA certification information Use in an environment...

Отзывы: