Command Reference
R&S
®
ZNB/ZNBT
885
User Manual 1173.9163.02 ─ 53
Manual operation:
See
8.3.1.20
CALCulate:TRANsform...
The
CALCulate:TRANsform...
commands convert measured data from one repre-
sentation to another and control the transformation into the time domain (see
ter 5.7.2, "Time Domain Analysis"
CALCulate<Chn>:TRANsform:COMPlex
.......................................................................... 885
CALCulate<Chn>:TRANsform:IMPedance:RNORmal
........................................................ 886
CALCulate<Chn>:TRANsform:TIME[:TYPE]
..................................................................... 886
CALCulate<Chn>:TRANsform:TIME:CENTer
.................................................................... 887
CALCulate<Chn>:TRANsform:TIME:DCHebyshev
............................................................ 887
CALCulate<Chn>:TRANsform:TIME:LPASs
......................................................................888
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
.....................................................888
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:CONTinuous
................................. 889
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate
................................ 889
CALCulate<Chn>:TRANsform:TIME:LPFRequency
........................................................... 890
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor
.................................................. 890
CALCulate<Chn>:TRANsform:TIME:SPAN
.......................................................................890
CALCulate<Chn>:TRANsform:TIME:STARt
...................................................................... 891
CALCulate<Chn>:TRANsform:TIME:STATe
...................................................................... 891
CALCulate<Chn>:TRANsform:TIME:STIMulus
..................................................................892
CALCulate<Chn>:TRANsform:TIME:STOP
.......................................................................892
CALCulate<Chn>:TRANsform:TIME:WINDow
...................................................................892
CALCulate<Chn>:TRANsform:TIME:XAXis
.......................................................................893
CALCulate<Chn>:TRANsform:COMPlex
<Result>
Converts S-parameters into converted (matched-circuit) Y-parameters or Z-parameters
and vice versa, assuming that port no. i is terminated with Z
0i
so that the three parame-
ter sets are equivalent and the following formulas apply:
ii
ii
i
ii
S
S
Z
Z
1
1
0
,
,
2
0
0
0
0
j
i
Z
Z
S
Z
Z
Z
j
i
ij
j
i
ij
ii
ii
ii
i
ii
Z
S
S
Z
Y
/
1
1
1
1
0
99
...,
,
1
,
,
,
/
1
2
0
0
0
0
j
i
j
i
Z
Z
Z
S
Z
Z
S
Y
ij
j
i
ij
j
i
ij
ij
SCPI Command Reference