Command Reference
R&S
®
ZNB/ZNBT
764
User Manual 1173.9163.02 ─ 53
Suffix:
<Chn>
.
Channel number used to identify the active trace
Return values:
<Boolean>
0 – skew check has passed
1 – skew check has failed
Usage:
Query only
Options:
R&S
ZNB/ZNBT-K20
CALCulate<Chn>:DTIMe:LIMit:FAIL:BEEP
<Boolean>
Defines whether the R&S
ZNB/ZNBT should make an audible beep on skew limit viola-
tions.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:DTIMe:LIMit:LIMit
<arg0>
Defines the limit value for the skew check.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<arg0>
Limit value in seconds or meters, depending on the format of the
current trace's stimulus axis (see
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:DTIMe:LIMit:STATe
<Boolean>
Activates/deactivates the skew limit check.
Use
CALCulate<Chn>:DTIMe:LIMit:LIMit
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNB/ZNBT-K20
SCPI Command Reference