![Rohde & Schwarz 1311.6010.22 User Manual Download Page 1225](http://html.mh-extra.com/html/rohde-and-schwarz/1311-6010-22/1311-6010-22_user-manual_14777681225.webp)
Command Reference
R&S
®
ZNB/ZNBT
1225
User Manual 1173.9163.02 ─ 53
Port-specific and general settings
The
SOURce:POWer...
subsystem comprises port-specific and general settings.
Port-specific settings are valid for the port specified by the numeric suffix
<PhyPt>
(
...:POWer<PhyPt>:...
). General settings are valid for all test ports of the ana-
lyzer; the port suffix is ignored. Refer to the description of the individual commands for
more information.
SOURce:POWer:CORRection...
The
SOURce:POWer:CORRection...
commands control a scalar source power cali-
bration.
SOURce:POWer:CORRection:PMETer:ID
...................................................................... 1225
SOURce<Ch>:POWer:CORRection:DATA
...................................................................... 1226
SOURce<Ch>:POWer:CORRection:DATA:PORT<PhyPt>
................................................1226
SOURce<Ch>:POWer:CORRection:DATA:PARameter<Wv>?
.......................................... 1227
SOURce<Ch>:POWer:CORRection:IMODulation:PORT
.................................................. 1228
SOURce<Ch>:POWer<PhyPt>:CORRection[:ACQuire]
................................................... 1229
SOURce<Ch>:POWer<PhyPt>:CORRection[:ACQuire]:VERification:RESult?
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:AVERage[:COUNt]
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:AVERage:NTOLerance
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:CFACtor
........................................1232
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:FLATness
..................................... 1232
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:METHod
....................................... 1233
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:PMReadings
................................. 1234
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:RRECeiver
....................................1234
SOURce<Ch>:POWer<PhyPt>:CORRection:DATA:PARameter<Wv>:COUNt?
SOURce<Ch>:POWer<PhyPt>:CORRection:GENerator<Gen>[:STATe]
............................ 1235
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:LTONe[:ACQuire]
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:UTONe[:ACQuire]
SOURce<Ch>:POWer<PhyPt>:CORRection:NREadings
................................................. 1237
SOURce<Ch>:POWer<PhyPt>:CORRection:OSOurces[:STATe]
.......................................1237
SOURce<Ch>:POWer<PhyPt>:CORRection:PPOWer
..................................................... 1238
SOURce<Ch>:POWer<PhyPt>:CORRection:PSELect
..................................................... 1238
SOURce<Ch>:POWer<PhyPt>:CORRection:STATe
........................................................ 1239
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient[:STATe]
....................................1239
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:CALibration
..............................1239
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:COUNt?
...................................1241
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DEFine<ListNo>
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>:ALL
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>[:DUMMy]
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:FEED
...................................... 1242
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:INSert<ListNo>
SOURce:POWer:CORRection:PMETer:ID
<PowerMeter>
Selects an external power meter for the scalar source power calibration (flatness cali-
bration).
SCPI Command Reference