Command Reference
R&S
®
ZNB/ZNBT
1195
User Manual 1173.9163.02 ─ 53
<Seg>
Sweep segment number. This suffix is ignored; the command
returns the sum of all segments.
Example:
See
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME
Usage:
Query only
Manual operation:
See
8.3.14.18
[SENSe:]SWEep...
The
[SENSe:]SWEep...
commands provide general settings to control the sweep.
Most of the settings have an impact on the sweep time.
........................................................................................ 1195
[SENSe<Ch>:]SWEep:AXIS:FREQuency
....................................................................... 1195
...............................................................................1196
.......................................................................................1197
[SENSe<Ch>:]SWEep:DETector:TIME
........................................................................... 1197
....................................................................................... 1198
[SENSe<Ch>:]SWEep:DWELl:IPOint
............................................................................. 1199
................................................................................ 1199
[SENSe<Ch>:]SWEep:GENeration:ANALog:CONDition?
................................................. 1199
.......................................................................................1200
.........................................................................................1201
......................................................................................... 1201
................................................................................1202
.........................................................................................1203
...................................................................................1204
[SENSe:]SWEep:COUNt:ALL
<Sweep>
Defines the number of sweeps to be measured in single sweep mode
(
OFF
). The setting is applied to all channels. Use
to define the sweep count for a single channel.
Setting parameters:
<Sweep>
Number of consecutive sweeps to be measured.
Range:
1 to 100000
*RST:
1
Example:
See
Chapter 9.2.4, "Data Handling"
Usage:
Setting only
Manual operation:
See
[SENSe<Ch>:]SWEep:AXIS:FREQuency
<Scale>
Selects either the channel base frequency or one of the port frequencies as the stimu-
lus axis in all diagrams of the active recall set. This command has no effect if no port-
specific frequencies are defined.