Command Reference
R&S
®
ZNB/ZNBT
809
User Manual 1173.9163.02 ─ 53
Manual operation:
See
8.3.1.9
CALCulate:GDAPerture...
The
CALCulate:GDAPerture...
commands configure the group delay measure-
ment.
CALCulate<Chn>:GDAPerture:SCOunt
<Steps>
Defines an aperture for the calculation of the group delay as an integer number of fre-
quency sweep steps.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Steps>
Number of steps
Range:
1 to 10000
*RST:
10
Example:
*RST; :CALC:FORM GDEL
Select group delay calculation for the active trace.
CALC:GDAP:SCO 15
Select an aperture of 15 steps.
Manual operation:
See
8.3.1.10
CALCulate:IAVerage
CALCulate<Chn>:IAVerage[:STATe]
<Boolean>
Turns infinite averaging on or off.
The averaging mode can be selected using
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
ON | OFF | 1 | 0
*RST:
0
Manual operation:
See
CALCulate<Chn>:IAVerage:MODE
<Mode>
Selects the quantities to be averaged if infinite averaging is enabled
(
CALCulate<Chn>:IAVerage[:STATe] ON
.
SCPI Command Reference