GUI Reference
R&S
®
ZNB/ZNBT
359
User Manual 1173.9163.02 ─ 53
The appearance of the limit fail symbols is defined in the "Define User Color Scheme"
dialog (see
Chapter 6.16.3.2, "Define User Color Scheme Dialog"
can choose between various options:
●
Change the trace color between failed measurement points.
●
Show or hide the colored squares.
Note:
●
Circle limit check and display of limit circles are independent of each other:
–
The limit circles can be displayed, no matter if the circle limit check is enabled.
–
If "Limit Check" is enabled, the ripple limits are checked, no matter if they are
displayed.
●
If result evaluation is limited to a user-defined
on page 357 is only performed inside this display circle.
●
The circle limits can only be checked if the trace format is complex. While a carte-
sian format is active, the limit circles are hidden and the circle limit check is sus-
pended.
●
If the limit check for (cartesian)
is enabled, it is also evaluated in complex
diagrams.
Figure 6-7: Simultaneous dB Mag limit line and circle check
Remote command:
CALCulate<Chn>:LIMit:CIRCle[:STATe]
CALCulate<Chn>:LIMit:CIRCle:FAIL?
CALCulate:LIMit:CIRCle:FAIL:ALL?
Limit Fail Beep
Activates or deactivates the fail beep. The fail beep is a low-tone acoustic signal that is
generated each time the analyzer detects an exceeded limit. No fail beep can be gen-
erated if the limit check is switched off.
Note:
In contrast to the R&S
ZNB, the R&S
ZNBT does not have a built-in audio
device and loudspeaker. To hear these sounds, connect a USB audio device to the
R&S
ZNBT or operate it via remote desktop.
Remote command:
CALCulate<Chn>:LIMit:CIRCle:SOUNd[:STATe]
Lines Softtool