FTMx_FMS field descriptions (continued)
Field
Description
If another fault condition is detected at the corresponding fault input before the clearing sequence is
completed, the sequence is reset so FAULTF2 remains set after the clearing sequence is completed for
the earlier fault condition.
0
No fault condition was detected at the fault input.
1
A fault condition was detected at the fault input.
1
FAULTF1
Fault Detection Flag 1
Set by hardware when fault control is enabled, the corresponding fault input is enabled and a fault
condition is detected at the fault input.
Clear FAULTF1 by reading the FMS register while FAULTF1 is set and then writing a 0 to FAULTF1 while
there is no existing fault condition at the corresponding fault input. Writing a 1 to FAULTF1 has no effect.
FAULTF1 bit is also cleared when FAULTF bit is cleared.
If another fault condition is detected at the corresponding fault input before the clearing sequence is
completed, the sequence is reset so FAULTF1 remains set after the clearing sequence is completed for
the earlier fault condition.
0
No fault condition was detected at the fault input.
1
A fault condition was detected at the fault input.
0
FAULTF0
Fault Detection Flag 0
Set by hardware when fault control is enabled, the corresponding fault input is enabled and a fault
condition is detected at the fault input.
Clear FAULTF0 by reading the FMS register while FAULTF0 is set and then writing a 0 to FAULTF0 while
there is no existing fault condition at the corresponding fault input. Writing a 1 to FAULTF0 has no effect.
FAULTF0 bit is also cleared when FAULTF bit is cleared.
If another fault condition is detected at the corresponding fault input before the clearing sequence is
completed, the sequence is reset so FAULTF0 remains set after the clearing sequence is completed for
the earlier fault condition.
0
No fault condition was detected at the fault input.
1
A fault condition was detected at the fault input.
39.4.19 Input Capture Filter Control (FTMx_FILTER)
This register selects the filter value for the inputs of channels.
Channels 4, 5, 6 and 7 do not have an input filter.
NOTE
Writing to the FILTER register has immediate effect and must
be done only when the channels 0, 1, 2, and 3 are not in input
modes. Failure to do this could result in a missing valid signal.
Memory map and register definition
KV4x Reference Manual, Rev. 2, 02/2015
932
Preliminary
Freescale Semiconductor, Inc.
Summary of Contents for freescale KV4 Series
Page 2: ...KV4x Reference Manual Rev 2 02 2015 2 Preliminary Freescale Semiconductor Inc...
Page 60: ...KV4x Reference Manual Rev 2 02 2015 60 Preliminary Freescale Semiconductor Inc...
Page 128: ...Debug Security KV4x Reference Manual Rev 2 02 2015 128 Preliminary Freescale Semiconductor Inc...
Page 138: ...Boot KV4x Reference Manual Rev 2 02 2015 138 Preliminary Freescale Semiconductor Inc...
Page 1358: ...KV4x Reference Manual Rev 2 02 2015 1358 Preliminary Freescale Semiconductor Inc...