45.5.1.5 Repeated START signal
The master may generate a START signal followed by a calling command without
generating a STOP signal first. This action is called a repeated START. The master uses
a repeated START to communicate with another slave or with the same slave in a
different mode (transmit/receive mode) without releasing the bus.
45.5.1.6 Arbitration procedure
The I2C bus is a true multimaster bus that allows more than one master to be connected
on it.
If two or more masters try to control the bus at the same time, a clock synchronization
procedure determines the bus clock. The bus clock's low period is equal to the longest
clock low period, and the high period is equal to the shortest one among the masters.
The relative priority of the contending masters is determined by a data arbitration
procedure. A bus master loses arbitration if it transmits logic level 1 while another master
transmits logic level 0. The losing masters immediately switch to slave receive mode and
stop driving SDA output. In this case, the transition from master to slave mode does not
generate a STOP condition. Meanwhile, hardware sets a status bit to indicate the loss of
arbitration.
45.5.1.7 Clock synchronization
Because wire AND logic is performed on SCL, a high-to-low transition on SCL affects
all devices connected on the bus. The devices start counting their low period and, after a
device's clock has gone low, that device holds SCL low until the clock reaches its high
state. However, the change of low to high in this device clock might not change the state
of SCL if another device clock is still within its low period. Therefore, the synchronized
clock SCL is held low by the device with the longest low period. Devices with shorter
low periods enter a high wait state during this time; see the following diagram. When all
applicable devices have counted off their low period, the synchronized clock SCL is
released and pulled high. Afterward there is no difference between the device clocks and
the state of SCL, and all devices start counting their high periods. The first device to
complete its high period pulls SCL low again.
Chapter 45 Inter-Integrated Circuit (I2C)
KV4x Reference Manual, Rev. 2, 02/2015
Freescale Semiconductor, Inc.
Preliminary
1249
Summary of Contents for freescale KV4 Series
Page 2: ...KV4x Reference Manual Rev 2 02 2015 2 Preliminary Freescale Semiconductor Inc...
Page 60: ...KV4x Reference Manual Rev 2 02 2015 60 Preliminary Freescale Semiconductor Inc...
Page 128: ...Debug Security KV4x Reference Manual Rev 2 02 2015 128 Preliminary Freescale Semiconductor Inc...
Page 138: ...Boot KV4x Reference Manual Rev 2 02 2015 138 Preliminary Freescale Semiconductor Inc...
Page 1358: ...KV4x Reference Manual Rev 2 02 2015 1358 Preliminary Freescale Semiconductor Inc...