Table 35-37. Comparator sample/filter controls (continued)
Mode #
CR1[EN]
CR1[WE]
CR1[SE]
CR0[FILTER_C
NT]
FPR[FILT_PER]
Operation
Comparator output is sampled on
every rising bus clock edge when
SAMPLE=1 to generate COUTA,
which is then resampled and filtered
to generate COUT.
All other combinations of CR1[EN], CR1[WE], CR1[SE], CR0[FILTER_CNT], and FPR[FILT_PER] are illegal.
For cases where a comparator is used to drive a fault input, for example, for a motor-
control module such as FTM, it must be configured to operate in Continuous mode so
that an external fault can immediately pass through the comparator to the target fault
circuitry.
Note
Filtering and sampling settings must be changed only after
setting CR1[SE]=0 and CR0[FILTER_CNT]=0x00. This resets
the filter to a known state.
35.4.1.1 Disabled mode (# 1)
In Disabled mode, the analog comparator is non-functional and consumes no power.
CMPO is 0 in this mode.
35.4.1.2 Continuous mode (#s 2A & 2B)
Functional description
KV4x Reference Manual, Rev. 2, 02/2015
738
Preliminary
Freescale Semiconductor, Inc.
Summary of Contents for freescale KV4 Series
Page 2: ...KV4x Reference Manual Rev 2 02 2015 2 Preliminary Freescale Semiconductor Inc...
Page 60: ...KV4x Reference Manual Rev 2 02 2015 60 Preliminary Freescale Semiconductor Inc...
Page 128: ...Debug Security KV4x Reference Manual Rev 2 02 2015 128 Preliminary Freescale Semiconductor Inc...
Page 138: ...Boot KV4x Reference Manual Rev 2 02 2015 138 Preliminary Freescale Semiconductor Inc...
Page 1358: ...KV4x Reference Manual Rev 2 02 2015 1358 Preliminary Freescale Semiconductor Inc...