
In this mode, the DECAP bit is automatically cleared by FTM when the edge selected by
channel (n+1) is captured. Therefore, while DECAP bit is set, the one-shot capture is in
process. When this bit is cleared, both edges were captured and the captured values are
ready for reading in the C(n)V and C(n+1)V registers.
Similarly, when the CH(n+1)F bit is set, both edges were captured and the captured
values are ready for reading in the C(n)V and C(n+1)V registers.
39.5.24.2 Continuous Capture mode
The Continuous Capture mode is selected when (DECAPEN = 1), and (MS(n)A = 1). In
this capture mode, the edges at the channel (n) input are captured continuously. The
ELS(n)B:ELS(n)A bits select the initial edge to be captured, and ELS(n+1)B:ELS(n+1)A
bits select the final edge to be captured.
The edge captures are enabled while DECAP bit is set. For the initial use, first the
CH(n)F and CH(n+1)F bits must be cleared, and then DECAP bit must be set to start the
continuous measurements.
When the CH(n+1)F bit is set, both edges were captured and the captured values are
ready for reading in the C(n)V and C(n+1)V registers. The latest captured values are
always available in these registers even after the DECAP bit is cleared.
In this mode, it is possible to clear only the CH(n+1)F bit. Therefore, when the CH(n+1)F
bit is set again, the latest captured values are available in C(n)V and C(n+1)V registers.
For a new sequence of the measurements in the Dual Edge Capture – Continuous mode,
clear the CH(n)F and CH(n+1)F bits to start new measurements.
39.5.24.3 Pulse width measurement
If the channel (n) is configured to capture rising edges (ELS(n)B:ELS(n)A = 0:1) and the
channel (n+1) to capture falling edges (ELS(n+1)B:ELS(n+1)A = 1:0), then the positive
polarity pulse width is measured. If the channel (n) is configured to capture falling edges
(ELS(n)B:ELS(n)A = 1:0) and the channel (n+1) to capture rising edges (ELS(n
+1)B:ELS(n+1)A = 0:1), then the negative polarity pulse width is measured.
The pulse width measurement can be made in
.
The following figure shows an example of the Dual Edge Capture – One-Shot mode used
to measure the positive polarity pulse width. The DECAPEN bit selects the Dual Edge
Capture mode, so it remains set. The DECAP bit is set to enable the measurement of next
Functional description
KV4x Reference Manual, Rev. 2, 02/2015
1008
Preliminary
Freescale Semiconductor, Inc.
Summary of Contents for freescale KV4 Series
Page 2: ...KV4x Reference Manual Rev 2 02 2015 2 Preliminary Freescale Semiconductor Inc...
Page 60: ...KV4x Reference Manual Rev 2 02 2015 60 Preliminary Freescale Semiconductor Inc...
Page 128: ...Debug Security KV4x Reference Manual Rev 2 02 2015 128 Preliminary Freescale Semiconductor Inc...
Page 138: ...Boot KV4x Reference Manual Rev 2 02 2015 138 Preliminary Freescale Semiconductor Inc...
Page 1358: ...KV4x Reference Manual Rev 2 02 2015 1358 Preliminary Freescale Semiconductor Inc...