647
Motion Task-related Alarm Codes
Section 11-5
Parameter
setting error
0372h
-
0379h
2019h
2019h
<PARAM>
System parameters:
• Attempted to change a parameter that
cannot be changed after restoring the
power.
• Attempted incorrect parameter setting.
Check the program so that correct values
can be set. (When specifying with vari-
ables, check if the substitution formula is
correct.)
Servo parameters:
• Attempted to change a parameter that
cannot be changed after restoring the
power.
• Attempted to set incorrect setting value
• Attempted to set incorrect number.
• Attempted to change parameter of other
tasks or undeclared axes.
Check and correct the program so that cor-
rect values can be set. (When specifying
with variables, check if the substitution for-
mula is correct.)
• Attempted to set servo parameters on vir-
tual axes or I/O axes.
Servo parameters cannot be set on virtual
axes and I/O axes. Correct the program.
<LATCH>
• The contents of [900Ah: Positive latch
enabled range] and [900Bh: Negative latch
enabled range] in the motor parameters
are not written correctly.
After checking the applicable axis and if
the motor model is correct, transfer the
motor parameters and save them to F-
ROM (when individual, specify servo
parameter), and restore the power.
<SPEED>
• The contents of [900Dh: Position loop
gain] and [900Eh: Position loop gain index]
in the motor parameter are not written cor-
rectly.
After checking the applicable axis and if
the motor model is correct, transfer the
motor parameters and save them to F-
ROM (when individual, specify servo
parameter), and restore the power.
When
PARAM,
LATCH,
SPEED are
executed.
Deceler-
ation
stop
Enabled
Axis declara-
tion error
201Ah 201Ah Axis other than servo/virtual axis is included
in the axis declaration.
Check the parameter [P1AA02: MECHA-
TROLINK-II device classification] of the
applicable axis. If the setting of the parame-
ter is correct, correct the program.
When
PROG is
executed.
Deceler-
ation
stop
Enabled
Name
Error log
Alarm
code
Cause and remedy
Timing
Rank
Reset
Error
code
Detail
code
Summary of Contents for CS1W-MCH71 -
Page 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Page 3: ...iv ...
Page 29: ...xxx ...
Page 33: ...xxxiv ...
Page 35: ...xxxvi ...
Page 39: ...xl ...
Page 69: ...24 Performance Section 1 7 ...
Page 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Page 283: ...238 Saving Data Section 5 4 ...
Page 417: ...372 Command Details Section 6 3 ...