xxix
Torque to Position Control Switching
Speed to Position Control Switching
Previous versions
Current version (Unit Ver. 2.0 or later)
Switching from torque control to position
control using the TORQUR command is
executed when the axis feedback speed
reaches 0.
• Switching from torque control to position
control using the TORQUR command is
executed by switching to position control
when the axis feedback speed reaches
the speed specified in a parameter
(specified by a percentage of the rated
speed).
• The following newly added parameter
uses part of the axis parameter area
that was previously reserved.
Previous versions
Current version (Unit Ver. 2.0 or later)
Switching from speed control to position
control using the SPEEDR command is
executed when the axis feedback speed
reaches 0.
• Switching from speed control to position
control using the SPEEDR command is
executed when the axis feedback speed
reaches the speed specified in a param-
eter (specified by a percentage of the
rated speed).
• The following newly added parameter
uses part of the axis parameter area
that was previously reserved.
Number
Name
P3AA09
Position control switching
speed
Setting range: 0 to 32,767
(0.01%)
Number
Name
P3AA09
Position control switching
speed
Setting range: 0 to 32,767
(0.01%)
Summary of Contents for CS1W-MCH71 -
Page 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Page 3: ...iv ...
Page 29: ...xxx ...
Page 33: ...xxxiv ...
Page 35: ...xxxvi ...
Page 39: ...xl ...
Page 69: ...24 Performance Section 1 7 ...
Page 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Page 283: ...238 Saving Data Section 5 4 ...
Page 417: ...372 Command Details Section 6 3 ...