xiii
Zones
Signed Master Axis MOVELINK Command
Indirect Writing of Position Data
Previous versions
(Unit Ver. 2.1 and earlier)
Current version
(Unit Ver. 3.0)
Zones are not supported.
A maximum of 32 zone bits are available.
Zone bit: A bit that turns ON when any variable is
within the set range, and turns OFF when the
variable is outside of the range.
The previous function and the new function can
be switched using the following parameter.
• Parameter number: P00011 (Reserved in previ-
ous unit versions.)
• Setting: 0 to 32
0: Default. Same as previous function.
1 to 32: Use zone bits 1 to 32.
Parameters and variables that were previously
reserved are used to set zone upper and lower
limits.
For details, refer to
Previous versions
(Unit Ver. 2.1 and earlier)
Current version (Unit Ver. 3.0)
The main axis input sign is ignored
and data is read as an absolute
travel distance.
The main axis input sign is evaluated and the
data is read as a signed travel distance.
This function enables the main axis to use the
feedback speed of an axis traveling at low
speed.
Previous versions
(Unit Ver. 2.1 and earlier)
Current version (Unit Ver. 3.0)
Position data can be indirectly
read but cannot be indirectly writ-
ten.
Position data can be both read and written indi-
rectly.
Example: Indirect Writing
@PL0000 = 1234;
“1234” will be assigned as the contents of the
address set in PL0000.
This function does not affect previous functional-
ity.
Summary of Contents for CS1W-MCH71 -
Page 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Page 3: ...iv ...
Page 29: ...xxx ...
Page 33: ...xxxiv ...
Page 35: ...xxxvi ...
Page 39: ...xl ...
Page 69: ...24 Performance Section 1 7 ...
Page 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Page 283: ...238 Saving Data Section 5 4 ...
Page 417: ...372 Command Details Section 6 3 ...