437
Interface Specifics
Section 7-4
Timing Chart
Basic Operation:
The timing chart will be the same as the above even at error completions. Use
the bit [Unit Alarm] to confirm normal completion or error completion. (Confirm
with the alarm as it seldom happens.)
If [Servo Parameter Save] is turned OFF before completion:
Function
• The present value of the operation data such as positions, speed, etc.
unique to each axis is output as monitor data.
• Though data unique to each axis is handled, selection is made for the
Unit. (Monitor data cannot be selected for each axis.)
1
0
1
0
Tu
Tu
When [Flash Save Completed] is
turned ON, [Servo Parameter
Save] will be turned OFF.
When [Servo Parameter Save] is
turned OFF, [Flash Save
Completed] will be turned OFF.
Current
Updated
Unit Control Bit:
Servo Parameter Save
Unit Status Bit:
Flash Save Completed
Data in Flash Memory
1
0
1
0
Turning OFF after the reception
will not interrupt processing.
[Flash Save Completed] will not be turned
ON because [Servo Parameter Save] is
already OFF at completion of saving.
Current
Updated
Unit Control Bit:
Servo Parameter Save
Unit Status Bit:
Flash Save Completed
Data in Flash Memory
Word
Variable
Bit
Name
I/O
n+0
IW0300
12-15
Present Value Monitor Select
Output
Summary of Contents for CS1W-MCH71 -
Page 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Page 3: ...iv ...
Page 29: ...xxx ...
Page 33: ...xxxiv ...
Page 35: ...xxxvi ...
Page 39: ...xl ...
Page 69: ...24 Performance Section 1 7 ...
Page 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Page 283: ...238 Saving Data Section 5 4 ...
Page 417: ...372 Command Details Section 6 3 ...