![Omron CS1W-MCH71 - Operation Manual Download Page 24](http://html1.mh-extra.com/html/omron/cs1w-mch71/cs1w-mch71_operation-manual_742367024.webp)
xxv
Setting the Number of Parallel Branches for Each Task
Present Position Preset to Establish Origin
Servo OFF for Deceleration Stop Signal
Previous version
(Unit Ver. 2.0)
Current version
(Unit Ver. 3.0)
The number of branches and the
number of commands that can be
executed are the same for each
task.
The number of branches and the number of
instructions that can be executed can be set
individually for each task, enabling fine adjust-
ment of the Unit cycle.
The previous function and the new function can
be switched using the following parameter.
• Parameter number: P00004
• Bit 11 (Reserved in previous unit versions.)
0: Default. Same as previous function.
1: Individually set the number of branches and
the number of commands that can executed
in each task.
Previously reserved parameters are used to set
the number of parallel branches individually for
each task.
Previous version
(Unit Ver. 2.0)
Current version
(Unit Ver. 3.0)
The origin is not established when
the present position is set to the
preset value.
The origin is established when the present posi-
tion is set to the preset value.
The previous function and the new function can
be switched using the following parameter.
• Parameter number: P00004
• Bit 12 (Reserved in previous unit versions.)
0: Default. Same as previous function.
1: Origin established for preset.
Previous version
(Unit Ver. 2.0)
Current version
(Unit Ver. 3.0)
When the deceleration stop signal
for the Unit turns ON, all axes are
decelerated to a stop.
When the deceleration stop signal for the Unit
turns ON, the servo can be turned OFF for all
axes. The operation for servo OFF is set in the
Servo Driver parameters.
The previous function and the new function can
be switched using the following parameter.
• Parameter number: P00004
• Bit 10 (Reserved in previous unit versions.)
0: Default. Same as previous function.
1: Servo OFF
Summary of Contents for CS1W-MCH71 -
Page 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Page 3: ...iv ...
Page 29: ...xxx ...
Page 33: ...xxxiv ...
Page 35: ...xxxvi ...
Page 39: ...xl ...
Page 69: ...24 Performance Section 1 7 ...
Page 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Page 283: ...238 Saving Data Section 5 4 ...
Page 417: ...372 Command Details Section 6 3 ...