10
Reference time: d0c5fc32.92c70b1e Wed, Dec 29 2010 18:28:02.573
System poll interval: 8 s
Table 5 Command output
Field
Description
Clock status
Status of the system clock:
•
synchronized
—The system clock has been synchronized.
•
unsynchronized
—The system clock has not been synchronized.
Clock stratum
Stratum level of the system clock.
System peer
IP address of the selected NTP server.
Local mode
Operation mode of the local device:
•
unspec
—The mode is unspecified.
•
active
—Active mode.
•
passive
—Passive mode.
•
client
—Client mode.
•
server
—Server mode.
•
broadcast
—Broadcast or multicast server mode.
•
bclient
—Broadcast or multicast client mode.
Reference clock ID
For an IPv4 NTP server:
The field represents the IP address of the remote server when the local device is
synchronized to a remote NTP server.
The field represents the local clock when the local device uses the local clock as the
reference source.
•
When the local clock has a stratum level of 1, this field displays
LOCL
.
•
When the local clock has any other stratum, this field displays the IP address
of the local clock.
For an IPv6 NTP server:
The field represents the MD5 digest of the first 32 bits of the IPv6 address of the
remote server when the local device is synchronized to a remote IPv6 NTP server.
The field represents the local clock when the local device uses the local clock as the
reference source.
•
When the local clock has a stratum level of 1, this field displays
LOCL
.
•
When the local clock has any other stratum, this field displays the MD5 digest
of the first 32 bits of the IPv6 address of the local clock.
Leap indicator
Alarming status:
•
00
—Normal.
•
01
—Leap second, indicates that the last minute in a day has 61 seconds.
•
10
—Leap second, indicates that the last minute in a day has 59 seconds.
•
11
—Time is not synchronized.
Clock jitter
Difference between the system clock and reference clock, in seconds.
Stability
Clock frequency stability. A lower value represents better stability.
Clock precision
Accuracy of the system clock.
Root delay
Roundtrip delay from the local device to the primary NTP server, in milliseconds.
Root dispersion
Maximum error of the system clock relative to the primary NTP server, in
milliseconds.
Reference time
Reference timestamp.
System poll interval
System polling interval in seconds.
Summary of Contents for SOHO IE4300
Page 285: ...i Contents Tcl commands 1 cli 1 tclquit 1 tclsh 2...
Page 288: ...i Contents Python commands 1 exit 1 python 1 python filename 2...
Page 291: ...i Contents Automatic configuration commands 1 autodeploy udisk enable 1...
Page 323: ...25 Sysname Ten GigabitEthernet1 0 51 undo shutdown Related commands irf port...
Page 465: ...ii stp vlan enable 55 vlan mapping modulo 55...
Page 602: ...12 Related commands display mvrp statistics...
Page 609: ...i Contents VLAN mapping commands 1 display vlan mapping 1 vlan mapping 2...
Page 678: ...9 Related commands reset pppoe relay statistics...
Page 846: ...i Contents Basic IP forwarding commands 1 display fib 1 ip forwarding table save 2...
Page 1770: ...i Contents Time range commands 1 display time range 1 time range 1...
Page 2026: ...34 Related commands display mac authentication...
Page 2028: ...ii...
Page 2143: ...i Contents User profile commands 1 display user profile 1 user profile 2...
Page 2308: ...61 ipsec transform set...
Page 2531: ...i Contents SAVI commands 1 ipv6 savi down delay 1 ipv6 savi log enable 1 ipv6 savi strict 2...
Page 2534: ...3 Sysname ipv6 savi strict Related commands ipv6 verify source...
Page 2791: ...14 Sysname track 1 Related commands delay display track...
Page 2939: ...9 sntp authentication keyid sntp reliable authentication keyid...