72
Related commands
prefix-suppression
ospfv3 primary-path-detect bfd
Use
ospfv3 primary-path-detect bfd
to enable BFD for OSPFv3 FRR.
Use
undo ospfv3 primary-path-detect bfd
to disable BFD for OSPFv3 FRR.
Syntax
ospfv3 primary-path-detect bfd
{
ctrl
|
echo
}
[
instance
instance-id
]
undo ospfv3 primary-path-detect bfd
[
instance
instance-id
]
Default
BFD is disabled for OSPFv3 FRR.
Views
Interface view
Predefined user roles
network-admin
Parameters
ctrl
: Enables BFD control packet mode.
echo
: Enables BFD echo packet mode.
instance
instance-id
: Specifies an instance by its ID in the range of 0 to 255. The default is 0.
Usage guidelines
This command enables OSPFv3 FRR to use BFD to detect primary link failures.
Examples
# On VLAN-interface 10, enable BFD echo packet mode for OSPFv3 FRR.
<Sysname> system-view
[Sysname] ospfv3 1
[Sysname-ospfv3-1] fast-reroute lfa
[Sysname-ospfv3-1] quit
[Sysname] bfd echo-source-ipv6 1::1
[Sysname] interface vlan-interface 10
[Sysname-Vlan-interface10] ospfv3 primary-path-detect bfd echo
ospfv3 timer dead
Use
ospfv3 timer dead
to set the OSPFv3 neighbor dead time.
Use
undo ospfv3 timer dead
to remove the configuration.
Syntax
ospfv3 timer dead
seconds
[
instance instance-id
]
undo ospfv3 timer dead
[
instance instance-id
]
Summary of Contents for SOHO IE4300
Page 285: ...i Contents Tcl commands 1 cli 1 tclquit 1 tclsh 2...
Page 288: ...i Contents Python commands 1 exit 1 python 1 python filename 2...
Page 291: ...i Contents Automatic configuration commands 1 autodeploy udisk enable 1...
Page 323: ...25 Sysname Ten GigabitEthernet1 0 51 undo shutdown Related commands irf port...
Page 465: ...ii stp vlan enable 55 vlan mapping modulo 55...
Page 602: ...12 Related commands display mvrp statistics...
Page 609: ...i Contents VLAN mapping commands 1 display vlan mapping 1 vlan mapping 2...
Page 678: ...9 Related commands reset pppoe relay statistics...
Page 846: ...i Contents Basic IP forwarding commands 1 display fib 1 ip forwarding table save 2...
Page 1770: ...i Contents Time range commands 1 display time range 1 time range 1...
Page 2026: ...34 Related commands display mac authentication...
Page 2028: ...ii...
Page 2143: ...i Contents User profile commands 1 display user profile 1 user profile 2...
Page 2308: ...61 ipsec transform set...
Page 2531: ...i Contents SAVI commands 1 ipv6 savi down delay 1 ipv6 savi log enable 1 ipv6 savi strict 2...
Page 2534: ...3 Sysname ipv6 savi strict Related commands ipv6 verify source...
Page 2791: ...14 Sysname track 1 Related commands delay display track...
Page 2939: ...9 sntp authentication keyid sntp reliable authentication keyid...
Page 2967: ...27 Related commands apply poe profile poe enable poe max power interface view poe priority...