5
Field
Description
Link
Link state of the IRF port:
•
UP
—The IRF link is up.
•
DOWN
—The IRF link is down because the port has no physical link or
has not been activated by the
irf-port-configuration
active
command.
•
DIS
—No physical interfaces have been bound to the IRF port.
•
TIMEOUT
—IRF hello interval has timed out.
•
ISOLATE
—The device is isolated from the IRF fabric. This issue might
be caused by the following reasons:
The IRF fabric does not support the device model.
The maximum number of member devices has exceeded the upper
limit.
neighbor
IRF member ID of the device connected to the IRF port.
This field displays three hyphens (---) if no device is connected to the port.
Belong To
IRF fabric that has the device, represented by the CPU MAC address of the
master in the IRF fabric.
Related commands
display irf
display irf configuration
display mad
Use
display mad
to display MAD status and settings.
Syntax
display mad
[
verbose
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
verbose
: Displays detailed MAD information. If you do not specify this keyword, the command only
displays whether a MAD mechanism is enabled or disabled.
Examples
# Display brief MAD information.
<Sysname> display mad
MAD ARP disabled.
MAD ND disabled.
MAD LACP enabled.
MAD BFD enabled.
# Display detailed MAD information.
<Sysname> display mad verbose
Multi-active recovery state: No
Summary of Contents for SOHO IE4300
Page 285: ...i Contents Tcl commands 1 cli 1 tclquit 1 tclsh 2...
Page 288: ...i Contents Python commands 1 exit 1 python 1 python filename 2...
Page 291: ...i Contents Automatic configuration commands 1 autodeploy udisk enable 1...
Page 323: ...25 Sysname Ten GigabitEthernet1 0 51 undo shutdown Related commands irf port...
Page 465: ...ii stp vlan enable 55 vlan mapping modulo 55...
Page 602: ...12 Related commands display mvrp statistics...
Page 609: ...i Contents VLAN mapping commands 1 display vlan mapping 1 vlan mapping 2...
Page 678: ...9 Related commands reset pppoe relay statistics...
Page 846: ...i Contents Basic IP forwarding commands 1 display fib 1 ip forwarding table save 2...
Page 1770: ...i Contents Time range commands 1 display time range 1 time range 1...
Page 2026: ...34 Related commands display mac authentication...
Page 2028: ...ii...
Page 2143: ...i Contents User profile commands 1 display user profile 1 user profile 2...
Page 2308: ...61 ipsec transform set...
Page 2531: ...i Contents SAVI commands 1 ipv6 savi down delay 1 ipv6 savi log enable 1 ipv6 savi strict 2...
Page 2534: ...3 Sysname ipv6 savi strict Related commands ipv6 verify source...
Page 2791: ...14 Sysname track 1 Related commands delay display track...
Page 2939: ...9 sntp authentication keyid sntp reliable authentication keyid...
Page 2967: ...27 Related commands apply poe profile poe enable poe max power interface view poe priority...