20
display environment
Use
display environment
to display temperature information.
Syntax
display environment
[
slot
slot-number
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot
slot-number
: Specifies an IRF member device by its member ID. If you do not specify a
member device, this command displays temperature information for all member devices.
Examples
# Display information about all temperature sensors on the device.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
1 hotspot 1 69 0 84 98 NA
1 hotspot 2 67 0 84 98 NA
1 hotspot 3 33 0 100 110 NA
1 hotspot 4 33 0 100 110 NA
1 hotspot 5 38 0 100 110 NA
1 hotspot 6 36 0 100 110 NA
1 hotspot 7 35 0 100 110 NA
1 hotspot 8 42 0 100 110 NA
Table 6 Command output
Field
Description
System Temperature
information (degree centigrade)
Temperature information (°C).
sensor
Temperature sensor:
hotspot
—Hotspot sensor.
Slot
Sensor position.
Temperature
Current temperature.
Lower
Lower temperature limit. If the device does not support this field, this field
displays
NA
.
Warning
Warning temperature threshold. If the device does not support this field,
this field displays
NA
.
Alarm
Alarming temperature threshold. If the device does not support this field,
this field displays
NA
.
Shutdown
Shutdown temperature threshold. When the sensor temperature reaches
the limit, the system shuts down automatically. If the device does not
Summary of Contents for SOHO IE4300
Page 285: ...i Contents Tcl commands 1 cli 1 tclquit 1 tclsh 2...
Page 288: ...i Contents Python commands 1 exit 1 python 1 python filename 2...
Page 291: ...i Contents Automatic configuration commands 1 autodeploy udisk enable 1...
Page 323: ...25 Sysname Ten GigabitEthernet1 0 51 undo shutdown Related commands irf port...
Page 465: ...ii stp vlan enable 55 vlan mapping modulo 55...
Page 602: ...12 Related commands display mvrp statistics...
Page 609: ...i Contents VLAN mapping commands 1 display vlan mapping 1 vlan mapping 2...
Page 678: ...9 Related commands reset pppoe relay statistics...
Page 846: ...i Contents Basic IP forwarding commands 1 display fib 1 ip forwarding table save 2...
Page 1770: ...i Contents Time range commands 1 display time range 1 time range 1...
Page 2026: ...34 Related commands display mac authentication...
Page 2028: ...ii...
Page 2143: ...i Contents User profile commands 1 display user profile 1 user profile 2...
Page 2308: ...61 ipsec transform set...
Page 2531: ...i Contents SAVI commands 1 ipv6 savi down delay 1 ipv6 savi log enable 1 ipv6 savi strict 2...
Page 2534: ...3 Sysname ipv6 savi strict Related commands ipv6 verify source...
Page 2791: ...14 Sysname track 1 Related commands delay display track...
Page 2939: ...9 sntp authentication keyid sntp reliable authentication keyid...
Page 2967: ...27 Related commands apply poe profile poe enable poe max power interface view poe priority...