background image

Digital Cam Switch Unit

CamCon DC30

Digitronic Automationsanlagen GmbH

Steinbeisstraße 3

D - 72636 Frickenhausen

Tel. (+49)7022/40590-0

Fax -10

Auf der Langwies 1

D - 65510 Hünstetten-Wallbach

Tel.(+49)6126/9453-0

Fax -42

Internet: http://www.digitronic.com

E-Mail: [email protected]

Summary of Contents for CamCon DC30

Page 1: ...Digitronic Automationsanlagen GmbH Steinbeisstra e 3 D 72636 Frickenhausen Tel 49 7022 40590 0 Fax 10 Auf der Langwies 1 D 65510 H nstetten Wallbach Tel 49 6126 9453 0 Fax 42 Internet http www digitr...

Page 2: ...above mentioned limits to liability do not apply to insurance of named characteristics and damages which were caused deliberately or through negligence Protection The CamCon DC30 and this instruction...

Page 3: ...6 2 4 The zero point correction 14 6 2 5 The dead time compensation 14 6 2 6 Setting of the programming mode 14 6 3 Cam programming in the programming mode 0 15 6 3 1 Selecting an output 15 6 3 2 Sea...

Page 4: ...pensation of the mechanical delay time of switch units Voltage supply 24V DC 20 Carrier rail assembly according to EN 50022 on CamCon DC16 and DC90 Switchboard norm encasement 144 x 144 x 63mm accordi...

Page 5: ...utput signals occur if the 3 cam plates turn anticlockwise past a sensor which scans the cams on the 0 axis The duration of the activation of a mechanical cam switch unit i e the range between the on...

Page 6: ...an impulse to the magnetic valve This opens the glue nozzle for a short time out of which the drop of glue then shoots Between the placing of the impulse and the falling of the drop passes a certain...

Page 7: ...avels by the distance x vpaper Tdead altogether 1m s 30ms 30mm further on The switching point of the magnetic valve has to be transfered 30 to the front to compensate this delay time If one doubles th...

Page 8: ...itching point is determined at a speed of e g 50 min 1 In our example the programmed switching point is at 200 degrees The second measurement occurs at a speed of 80 min 1 The needed switching point h...

Page 9: ...unding point of the switchboard door in the shortest possible way All cable connections must be done in a cold state The connection cables e g for the measuring system or the serial interface must be...

Page 10: ...4V DC for encoder Pin 7 0V supply Pin 8 Output 1 Pin 9 Output 2 Pin 10 Output 3 Pin 11 Output 4 Pin 12 Output 5 Pin 13 Output 6 Pin 14 Output 7 Pin 15 Output 8 Pin 16 24V DC supply only for the CamCon...

Page 11: ...p clock impulse Tmono mono flop time 25 s Attention Use only a covered double entwined connection cable The wiring should not be near power current lines Ground the covers at both sides 4 3 The output...

Page 12: ...tions minute By pressing the key the angular position of the encoder e g is displayed If the key is pressed the display will show the rotatory speed 5 4 The keyboard The key serves for increasing the...

Page 13: ...il the display shows either a number or 3 Press the key four times 4 Press the key four times 5 Press the key about 2sec until is displayed 6 Press the key about 2sec until the display goes out 7 Rele...

Page 14: ...r position to 0 by pressing the key or the key so that the mechanical and the electronic zero point coincide The display shows 6 2 5 The dead time compensation After you press the key the display show...

Page 15: ...ivation and the deactivation points 6 3 4 Shifting the activation point By pressing the key you leave the Preset mode and enter the Activation point mode A pressing of the key or the key shifts the ac...

Page 16: ...s the key and keep it pressed until is displayed 6 If you have released the key too early or too late you can adjust the preselection to 100 with the or the key 7 Press the key the activation point is...

Page 17: ...o early or too late you can adjust the preselection to 300 with the or the key 7 Press the key the activation point is displayed 8 Press the key to program the deactivation point 9 Press the key and k...

Page 18: ...he key to program the activation point The display shows 7 Press the key and keep it pressed until the display shows CAUTION Do not keep the key pressed too long It is best to keep the key pressed unt...

Page 19: ...01 A short pressing of the key will lower the preset value 100 in our example by 1 and then set a new activation point at e g 99 6 4 3 Shifting the deactivation point Pressing the key once more leads...

Page 20: ...ressed until the display shows 8 If you have released the key too early or too late you can adjust the deactivation point to 200 with the or the key 9 Press the key You return to the standard display...

Page 21: ...em constants Press the key shortly User key for system constants Press the key about 2 sec Encoder resolution Press the key shortly Encoder F R switching Press the key shortly Zero point correction Pr...

Page 22: ...encoder resolution Check the wiring to the encoder or the input of the encoder resolution When the error is corrected press any key to clear the error message of the display Problem The display shows...

Page 23: ...ection of the encoder is programmed by CamCon Length of the connecting cable between encoder and CamCon 200m Data security memory EEPROM Supply voltage 24V DC 20 Encoder supply voltage with 24V DC ove...

Page 24: ...or speed 12 Encoder 11 Encoder resolution 14 F R change over 14 Grounding pins 9 Initialization 13 Installation 9 Installation procedures 9 Keyboard 12 Leaving cam programming 16 millenium 2 Operatio...