Screen Reference
Feature-Related System Parameters
862
Administrator’s Guide for Avaya Communication Manager
November 2003
Vector Disconnect Timer (min)
Enter the number of minutes, or blank that a trunk should remain connected to a vector.
Wait Answer Supervision Timer
See
Unanswered DID Call Timer (seconds)
for more information.
ITALIAN DCS PROTOCOL
The next three fields control the Italian DCS Protocol feature.
Apply Intercept Locally
This field appears if the
Italian Protocol Enabled
field is y.
Enforce PNT-to-PNT Restrictions
This field appears if the
Italian Protocol Enabled
field is y.
Valid entries
Usage
1 to 240
The number of minutes that you enter determines when the trunk
will be disconnected if the
Disconnect Supervision-In
or
Disconnect Supervision-Out
fields on the Trunk Group screen
are n.
blank
Enter blank if you do not want Avaya Communication Manager to
initiate a disconnect.
Valid entries
Usage
y
Enter y to enable this feature on a systemwide basis. When y is
entered in this field, calls to stations unanswered after 50 seconds
are dropped.
n
When n is entered in this field, unanswered calls drop only when
the calling party goes on-hook.
Valid entries
Usage
y/n Enter
y to indicate that DID/CO intercept treatment will be applied
locally instead of on the originating server/switch.
Valid entries
Usage
y/n Enter
y to indicate that restrictions and denial of PNT-to-PNT
connections will be enforced when the EDCS message is
unavailable. A y in this field means restrictions will be enforced.