Screen Reference
Loudspeaker Paging
Administrator’s Guide for Avaya Communication Manager
1061
November 2003
Port
This field assigns a port on an auxiliary trunk circuit pack to a paging zone. Enter the necessary
characters.
Voice Paging — COR
This field assigns a Class of Restriction to a paging zone.
Valid entries
Usage
01 through 44
(DEFINITY R) or
01 through 03
(DEFINITY CSI, SI) or
1 through 64
(S8700 IP-Connect / S8700
Multi-Connect / S8300 Media
Server)
First and second characters are the cabinet number
A through E
Third character is the carrier
0 through 20
Fourth and fifth character are the slot number
01 through 04
(Analog TIE trunks)
01 through 31
Six and seventh characters are the circuit number
1 through 80
(DEFINITY R, CSI) or
1 through 10 (DEFINITY SI)
or
1 through 250
(S8700 IP-Connect / S8700
Multi-Connect / S8300 Media
Server)
Gateway
V1 through V9
Module
01 through 31
Circuit
blank
Leave this field blank for unused paging zones.
Valid entries
Usage
0 through 95.
You can assign different classes of restriction to different zones.
blank
Leave this field blank for unused paging zones.