Screen Reference
System Parameters OCM Call Classification
1230
Administrator’s Guide for Avaya Communication Manager
November 2003
Field descriptions for page 1
Figure 357: System Parameters OCM Call Classification screen
Global Classifier Adjustment (dB)
Enter a number to specify the dB loss adjustment.
USA Default Algorithm
USA SIT Algorithm
Valid entries
Usage
0 to 15
0 is the least and 15 the most adjustment.
Valid entries
Usage
y/n
To use the default United States tone detection, set this field to y. If
you enter n, the US Special Information Tones (SIT) Algorithm
field appears.
Valid
entries
Usage
y
To use the United States (SIT) tone characteristics for SIT tone detection.
n
The system treats tones with the administered tone name “intercept” as if
they were SIT VACANT, and treats tones with the administered tone
name “information” as if they were SIT UNKNOWN.
Page 1 of 2
SYSTEM PARAMETERS OCM CALL CLASSIFICATION
TONE DETECTION PARAMETERS
Global Classifier Adjustment (dB): ___
USA Default Algorithm? _n_
USA SIT Algorithm? ___