Managing MultiMedia Calling
Multimedia Applications Server Interface
252
Administrator’s Guide for Avaya Communication Manager
November 2003
•
LWC Reception
— This field indicates whether the terminal can receive Leave Word Calling
(
LWC
) messages. Valid values are none, audix, and spe (for DEFINITY® Server R
configurations) or mas-spe (for DEFINITY® Server SI/DEFINITY® Server CSI configurations).
SPE-based LWC is not supported for MASI terminals. However, if embedded AUDIX is used
without a Data Control Link, you must administer MASI terminals to receive SPE-based LWC
messages. For such cases, the LWC feature is used by AUDIX messaging systems to activate and
deactivate message waiting lamps on MASI terminals.
•
CDR Privacy
— Indicates whether CDR Privacy is supported for this terminal. See
Call detail
recording
on page 1433 for more information.
•
AUDIX Name
— This field only appears on DEFINITY® Server R configurations. This field
contains the name of the AUDIX messaging adjunct for LWC messages. If the
LWC Reception
field is set to audix, this field must contain a name. The name must match a machine name on the
Adjunct Names screen.
Figure 27: MASI Terminal screen — page 3
•
Room
—
Enter up to 10 characters to identify the MASI terminal location. This field may be
blank.
•
Jack
—
Enter up to 5 characters to identify the location where the MASI terminal is connected.
This field may be left blank.
•
Cable
—
Enter up to 5 characters to identify the cable that connects the MASI terminal to the
system. This field may be left blank.
•
Floor
—
Enter up to 7 characters to identify the floor where the MASI terminal is located.
•
Building
—
Enter up to 7 characters to identify the building where the MASI terminal is located.
Valid entries are listed in the site table.
•
Button Assignments
— This field contains a call appearance button and is display only.
MASI TERMINAL
SITE DATA
Room: _______
Jack: _____
Cable: _____
Floor: _______
Building: _______
BUTTON ASSIGNMENTS
1: call-appr