Screen Reference
PRI Endpoint
1112
Administrator’s Guide for Avaya Communication Manager
November 2003
(Starting) Port
Enter the seven-character starting port of the PRI Endpoint. Enter the necessary characters.
TN
Width
Enter the number of adjacent DS0 ports beginning with the specified Starting Port, that make up the PRI
Endpoint.This field cannot be blank.
Valid entries
Usage
01 through 44
(DEFINITY R) or
01 through 03
(DEFINITY CSI, SI) or
1 through 64
(S8700 IP-Connect / S8700
Multi-Connect / S8300 Media
Server)
First and second characters are the cabinet number
A through E
Third character is the carrier
0 through 20
Fourth and fifth character are the slot number
01 through 04
(Analog TIE trunks)
01 through 31
Six and seventh characters are the circuit number
Valid entries
Usage
1–20 (DEFINITY CSI,
SI)
1–100 (DEFINITY R,
S8300 Media Server,
S8700 IP-Connect, S8700
Multi-Connect)
Enter the Tenant Partition number.
Valid entries
Usage
1 to 31
A width of 6 defines a PRI Endpoint that can support data rates up to
384 Kbps.