Screen Reference
Data modules
734
Administrator’s Guide for Avaya Communication Manager
November 2003
Connected to
Used with Data Line and Processor/Trunk (pdm selection) Data Module. This field shows to what the
Asynchronous Data Unit (ADU) is connected.
COS
Does not appear for ethernet or x.25. Enter the desired class of service.
COR
Does not appear for ethernet. Enter the desired class of restriction.
Data Extension
A display-only field indicating the extension assigned to the data module.
Destination Number
Used with X.25 and Processor Interface data modules. See Administration for Network Connectivity for
Avaya Communication Manager for more information.
DTE/DCE
Used with X.25 Data Modules. Specifies how the above endpoint type acts.
Valid entries
Usage
dte
Data Terminal Equipment. Used with Data Line and
Processor/Trunk Data Modules.
isn
Information Systems Network. Used with Data Line and
Processor/Trunk Data Modules.
Valid entries
Usage
0 through 15
Select the allowed features.
Valid entries
Usage
0 through 95
Select the allowed restriction.
Valid entries
Usage
dte
Data Terminal Equipment
dce
Data Communications Equipment