Screen Reference
Multifrequency-Signaling-Related Parameters
1076
Administrator’s Guide for Avaya Communication Manager
November 2003
Two port entries are required.Enter the necessary characters.
NOTE:
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number (port) 12.
Multifrequency-Signaling-Related
Parameters
This screen sets the system parameters associated with multifrequency signaling. This screen appears
when
Incoming Call Type
is group-ii-mfc and
Outgoing Call Type
is none. Page 2 of this screen (see
page 1085) appears when both
Incoming Call Type
and
Outgoing Call Type
are group-ii-mfc.
If the field
Use COR for All Group II Responses
is set to y, the
Group II Called Party Category
and
Use COR for Calling Party Category
fields do not appear.
Valid entries
Usage
01 through 44
(DEFINITY R) or
01 through 03
(DEFINITY CSI, SI) or
1 through 64
(S8700 IP-Connect / S8700
Multi-Connect / S8300 Media
Server)
First and second characters are the cabinet number
A through E
Third character is the carrier
0 through 20
Fourth and fifth character are the slot number
01 through 04
(Analog TIE trunks)
01 through 31
Six and seventh characters are the circuit number
1 through 80
(DEFINITY R, CSI) or
1 through 10 (DEFINITY SI)
or
1 through 250
(S8700 IP-Connect / S8700
Multi-Connect / S8300 Media
Server)
Gateway
V1 through V9
Module
01 through 31
Circuit