Managing Data Calls
Setting up DEFINITY LAN Gateway
Administrator’s Guide for Avaya Communication Manager
473
November 2003
Setting up DEFINITY LAN Gateway
Before you start
This section describes pre-administrative tasks associated with the Co-Resident DLG.
For S8100 Media Server Configurations
If you want to use a TN799 C-LAN circuit pack as the Ethernet Interface for the Co-Resident DLG,
proceed as follows:
1
Type display system-parameters customer-options and press
ENTER
.
2
Go to page 2 and make sure the
ASAI Link Core Capabilities
and/or
Computer Telephony
Adjunct Links
fields are y, and the
Co-Res DEFINITY LAN Gateway
field is y.
3
Type display node-names ip and press
ENTER
.
Make sure that there is a node name associated with the C-LAN. If there is not a node name, add
one.
4
Type display ip-interfaces and press
ENTER
.
Make sure the C-LAN is administered and its Ethernet port is enabled. If the C-LAN is not listed
(the
Type
field should display
C-LAN
, and the previously administered node name should appear
in the
Node Name / Local Node
field), add a C-LAN.
5
Type list data-module and press
ENTER
.
Make sure that the Ethernet port on the C-LAN is administered. If the Ethernet port is not listed,
add it with the
add data-module
command (the
Service Type
field should be Ethernet and the
Port
field should be port 17 on the TN799).
If you want to use a TN2314 circuit pack as the Ethernet Interface for the Co-Resident DLG, proceed as
follows:
1
Type display system-parameters customer-options and press
ENTER
.
2
Go to page 2 and make sure the
ASAI Link Core Capabilities
and/or
Computer Telephony
Adjunct Links
fields are y, and the
Co-Res DEFINITY LAN Gateway
field is y.
3
Go to page 4 and make sure that the
Processor Ethernet
field is y.
4
Type display ip-interfaces and press
ENTER
.
Make sure the PROCR is administered and its Ethernet port is enabled. If the PROCR is not listed
(
PROCR
should appear in the
Type
field and the previously administered node name should appear
in the
Node Name
field), add a PROCR.