Screen Reference
Trunk Group
1300
Administrator’s Guide for Avaya Communication Manager
November 2003
Short Holding Threshold
This field appears when the ACA Assignment field is y.
Short Holding Time (seconds)
This field appears when the ACA Assignment field is y.
Shuttle
This field appears when the
Group Type
field is co, fx, or wats, the Country field is 15, and the
Outgoing Dial Type
field is rotary. It can be administered on TN464D (or later release) or TN2199
circuit packs.
Signaling Group
This field displays the group number assigned when the group was added.
.
Start B Signal
This field appears when the
Country
field is 15 and the
Shuttle
field is y. Enter 1–3 to indicate which
B-signal should be used to start a call. The value administered in this field must be coordinated with your
central office. See
Start Position
on page 1301.
Valid entries
Usage
0 to 30
Enter the number of times the system will record a short holding
call before alerting an attendant to the possibility of a faulty trunk.
Enter 0 for no short holding calls.
Valid entries
Usage
0 to 160
Enter the length of time (in seconds) that the system considers as
being a short holding time. If 0 is entered, the system will not
consider short holding calls.
Valid entries
Usage
y/n
Enter y to enable MF shuttle signaling.
Valid entries
Usage
1
Start calls with signal B1 (first digit)
2
Start calls with signal B2 (next digit)
3
Start calls with signal B3 (previous digit)