A - 123
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4 Sys
m
ac Error Sta
tus C
o
des
A
A-4
-2 Err
or De
scriptions
Event name
Motor Overheat Error
Event code
08420000 hex
Description
The encoder detected the temperature that exceeded the protection level of motor.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after resetting
slave errors)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The temperature is high around
the motor
Adjust the temperature around the
motor to be within the range of the
operating temperature.
Adjust the ambient temperature to
be within the range of the operat-
ing temperature before using the
motor.
The motor is overloaded
Adjust the motor load ratio to be
within the specified range.
Adjust the operation before use, so
that the motor load ratio does not
become high for a long time.
Encoder failure
Replace the motor if this event
occurs repeatedly.
None
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 1501 hex
Event name
1-rotation Counter Error
Event code
08430000 hex
Description
The encoder detected a one-rotation counter error.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
There is excessive noise
Take noise countermeasures. If
this event occurs after you per-
formed noise countermeasures,
the motor is faulty. Replace the
motor.
Take noise countermeasures.
Failure due to vibration, impact,
condensation, foreign matter, etc.
Do not use the product in an area
surrounded by excessive foreign
matter. Also, do not allow foreign
matter to enter.
Attached
information
Attached information 1: System information
Precautions/
Remarks
AL status code: -, Error No.: 4400 hex
Содержание R88D-1SN ECT Series
Страница 544: ...7 Applied Functions 7 52 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 560: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 700: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 969: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 972: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 973: ......