4 - 69
4 Configuration and Wiring
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
4-3 Wiring
Con
fo
rm
ing
to
EMC Directi
ves
4
4-
3-2 Selecting
Connection
Component
DC Reactor Connection
As shown in the following figure, remove the short-circuit wire between N1 and N2, and connect the
DC Reactor between N1 and N2.
AC Reactor Connection
As shown in the following figure, connect the AC Reactor between the AC power supply for the main
circuit and Servo Drive.
Recommended Reactor External Dimensions
UZDA-B-OMR1S5575H
N1
N2
Servo Drive
DC Reactor
Remove the short-circuit wire between N1 and N2.
U
X
L1
L2
L3
U
V
W
X
Y
Z
AC Reactor
Servo Drive
AC input
(1.6)
2-terminal M5 screw
114
68
72
115
89
4-mounting hole
for M6 bolt
145 max.
80 max.
(16)
Terminal block top view
U
X
Содержание R88D-1SN ECT Series
Страница 544: ...7 Applied Functions 7 52 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 560: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 700: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 969: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 972: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 973: ......