Obey the following conditions when installing.
• Clearance with peripheral equipment: 50 mm min.
• Wire length: 3 m max.
Obey the following conditions along with the general installation conditions when installing.
• Installation Direction: Install the terminal block side of the unit in the gravity direction (downward).
Obey the following conditions along with the general installation conditions when installing.
• Installation Direction: Install the connector side of the unit in the gravity direction (downward).
• Tightening torque: 3.0 N·m
Specifications for attached connectors are shown below. Follow the specified length of stripped wire.
For a wiring procedure, refer to CNE of R88D-1SN150H-ECT of
Procedure for Wiring Terminal Block
and Procedure for Mounting Shield Clamp to Servo Drive
• Connector model: R88A-CN101E (832-1102/037-000 manufactured by WAGO)
• Length of stripped wire: 19±1 mm
4-1-4
External Regeneration Resistor and External Regeneration
Resistance Unit Installation Conditions
General Installation Conditions
External Regeneration Resistance Unit with Fan Installation Condi-
tions
External Regeneration Resistance Unit without Fan Installation Con-
ditions
Содержание R88D-1SN ECT Series
Страница 544: ...7 Applied Functions 7 52 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 560: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 700: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 969: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 972: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 973: ......